61 62
What the signs mean:
This is the actual tem-
perature at the panels
This is only a reading
- it cannot be adjusted
A minimum temp
requirement at the
panels for system to
next switch on
It is minimum set tem-
perature. If the
temperature drops
below set temperature
the system will turn off
An actual temperature
reading at the cylinder
This is the temp at the
cylinder
This is the minimum
required temperature at
the cylinder
This is just a reading
Pump speed This is just a reading
Please note: the menu item “additional settings” do not apply for DC12 and have no
function for the DC12
3. Settings
- This mode will be shown on the main display when you press the right button until you
see sign:
Settings•
SET
- Each setting has been marked by key numbers. A list of the key numbers is explained in
the instruction manual for DC 12
- I would like to highlight those which must be re-set so that the controller will work
efciently.
- The settings are divided into the two groups. One is without the password and second
group can be adjusted only with password.
Settings without the password
Key number: 8-62
- Minimum temperature required at the cylinder (pre-set by manufacturer) 60°C.
- Do not set this value above 70
o
C
How do you change the value?
While you are on the mode SET, press the TICK button. The key number (8-62)
will appear below hydraulic scheme. Press enter again and the pre-set value starts
ash. With right or left button you will be able to change the value. Press the TICK
button again. When you press the right button you will go to following key number
which is 8-63 and after another press to 8-85.