6.2.7 After you place the panels into the frame and connect the panels together using the
straight connectors and pipe inserts provided, t the wind clamps to the frame using
the nuts and bolts provided.
Option to raise the pitch
6.2.8 There are three different sizes of pitch extension frames:
(a) 500 mm which raises the pitch by about 15°
(b) 750 mm which raises the pitch by about 21°
(c) 1000 mm which raises the pitch by about 27°
6.2.9 (1) Fit the right angle connector on the top of the self sealing bolt tting on the
upper side screw extension rails
(2) Fit the right angle connector to the top of the self sealing bolt tting on the
lower L-rail